Wall Assembly R-Value

The whole-assembly R-value of a framed wall by the parallel-path method.

Run the calculator

Example

You enter

You get

Checked against published worked examples from: Continuous Insulation Council (Timothy Ahrenholz).

Details, formula, and sources

ScopeWhere the studs short-circuit the cavity insulation -- the wall performs below its center-of-cavity R. Reports both.

Formula or tableU_assembly = framing factor x 1/R_framing-path + (1 - factor) x 1/R_cavity-path; R = 1/U; framing path adds stud depth x 1.25 R/in.

Source and editionASHRAE Handbook of Fundamentals parallel-path (isothermal-planes) method (by name).

Free accessASHRAE Fundamentals licensed; air-film and material R-values widely published free.

What governsEstimate. AHJ and licensed professional govern.

API field namescavity_r, stud_depth_in, framing_factor, air_films_r, finish_layers_r, r_assembly, r_center