Surcharge Lateral Pressure on a Wall from a Line Load (Boussinesq)

Lateral pressure a concentrated surface load puts on a wall, by Boussinesq.

Run the calculator

Example

You enter

You get

Details, formula, and sources

The bulge of lateral pressure a concentrated surface load (a footing, wheel line, or crane outrigger set back from a wall) puts on it - which the uniform Ka q surcharge never captures: the NAVFAC DM-7.2 modified-Boussinesq sigma_h = (0.203 qL/H) n/(0.16 + n^2)^2 for m <= 0.4, doubled for a rigid non-deflecting wall (m = x/H, n = z/H). A 1,000 lb/ft line 4 ft back from a 10 ft wall peaks near 97 psf at shallow depth; set it farther back and it pushes less and deeper. Line load, single depth. A design aid; the geotechnical engineer of record governs.

m = x/H, n = z/H; m <= 0.4: sigma_h = (0.203 qL/H) n/(0.16 + n^2)^2; m > 0.4: sigma_h = (1.28 qL/H)(m^2 n)/(m^2 + n^2)^2.

The NAVFAC DM-7.2 modified-Boussinesq line-load lateral pressure on a rigid wall, the doubled elastic Boussinesq solution for an unyielding wall, by name.

NAVFAC DM-7.2 is public-domain and free online; the modified-Boussinesq surcharge relations are public.

Estimate. AHJ and licensed professional govern.

Field names used by the API: ql_plf, h_ft, x_ft, z_ft, m_ratio, n_ratio, sigma_h_psf