Wood Column Capacity (Slenderness)

Slenderness ratio, column stability factor Cp, allowable Fc-prime, and allowable axial capacity for a solid rectangular sawn-lumber column via the NDS Cp / Euler buckling basis.

Run the calculator

Formula and source

le/d governs (smaller dimension); FcE = 0.822*Emin/(le/d)^2; a = FcE/Fc*; c = 0.8 (sawn); Cp = (1+a)/(2c) - sqrt(((1+a)/(2c))^2 - a/c); Fc' = Fc**Cp; capacity = Fc'*b*d.

Per the NDS column-stability provisions (the Cp / Euler buckling basis), by name; reference design values user-supplied.

Audience

This tile is built for carpentry and the adjacent professions in the Carpentry and Construction group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.