Draft Beer Line Balancing

The beer-line length that balances a draft system so it pours right, not foamy or slow.

Run the calculator

Example

You enter

You get

Details, formula, and sources

at balance the applied CO2 pressure equals the line restriction (R per foot x length) plus the rise (0.5 psi/ft) plus the faucet (~1 psi), so line = (pressure - 0.5 x rise - 1) / R. A 12 psi system with a 4 ft rise on 3/16" vinyl (3.0 psi/ft) needs 3.0 ft of line. Set the pressure to the carbonation level first, then balance the line; restriction values are nominal per tubing size (3/16" vinyl 3.0, 1/4" 0.85, 3/16" barrier 2.2, 5/16" 0.4 psi/ft). Per the Brewers Association Draught Beer Quality Manual; measure the pour rate and trim.

line_length_ft = (applied_pressure_psi - 0.5 x rise_ft - 1) / R, where R is the tubing restriction (psi/ft): 3/16" vinyl 3.0, 1/4" vinyl 0.85, 3/16" barrier 2.2, 5/16" vinyl 0.4.

Draft-beer line balancing (the Brewers Association Draught Beer Quality Manual system-balance equation), by name; the dispense system and the beer govern.

The system-balance relation (applied pressure = total restriction) is published draught-beer practice; the tubing restriction is a nominal material property.

Estimate. AHJ and licensed professional govern.

Field names used by the API: applied_pressure_psi, rise_ft, tubing_type, line_length_ft