Expansion Joint / Loop Guide Spacing (EJMA 4D/14D)

Where the first two guides go so an expansion joint or loop compresses instead of buckling sideways.

Run the calculator

Example

You enter

You get

Details, formula, and sources

The first guide within four pipe diameters of the joint, the second within fourteen diameters of the first, per the Expansion Joint Manufacturers Association (EJMA) rule. A 4 in line (OD 4.5) guides at 18 in then 63 in past it (81 in from the joint); the distances scale directly with the diameter, the multipliers are the fixed rule. Beyond guide 2 the intermediate spacing comes from the EJMA table or the pipe-column stability calc. This places the planning guides; the anchor and joint selection govern.

first_guide = d1_mult x pipe_od (default 4 diameters from the joint); second_guide = d2_mult x pipe_od (default 14 diameters past the first guide); guide 2 is first_guide + second_guide from the joint.

The Expansion Joint Manufacturers Association (EJMA) 4-diameter / 14-diameter guide-placement rule and the manufacturer installation guides, by name.

The 4D/14D first-and-second-guide rule is the EJMA published placement standard, republished in every manufacturer's installation guide.

Estimate. AHJ and licensed professional govern.

Field names used by the API: pipe_od_in, d1_mult, d2_mult, first_guide_in, second_guide_in, guide2_from_joint_in