Chemical Application Rate (GPA)

The gallons per acre a sprayer applies, or the speed and nozzle flow that hit a target rate.

Run the calculator

Example

You enter

You get

Details, formula, and sources

GPA = (5940 * GPM) / (speed * spacing) and inverse for target GPA.

GPA = (5940 × GPM) / (speed_mph × spacing_in). The constant 5940 = 60 min/hr × 43 560 ft²/acre / (12 in/ft × ?)... derives from unit reconciliation.

ASABE EP367 (Guide for Preparing Field Sprayer Calibration Procedures) by name; manufacturer sprayer-calibration guides (John Deere, AGCO, Case IH) by name.

ASABE standards licensed; calibration principles free at most state-extension service pages (e.g., extension.psu.edu).

Read and follow the product label. The label is the law (FIFRA).

Field names used by the API: gpm, spacing_in, speed_mph, target_gpa, gpa, required_gpm