LED Tape Max Run Before the Far End Dims

The longest single end-fed run before the far end dims past your drop tolerance.

Run the calculator

Example

You enter

You get

Details, formula, and sources

len_max = voltage x sqrt(2 x (tolerance/100) / (power_per_ft x resistance_per_ft)). A 4.4 W/ft 12 V strip at 0.05 ohm/ft walls out at about 11.4 ft for a 10% drop; a 24 V strip reaches roughly double (the run scales with the voltage). Answers 'how far can I run this tape' instead of checking one length. Oversizing the PSU does not extend it -- power-inject or feed both ends. The strip datasheet governs.

len_max = voltage x sqrt(2 x (tolerance/100) / (power_per_ft x resistance_per_ft)); the inverse of led-tape-run's drop_pct = power_per_ft x resistance_per_ft x length^2 / (2 x voltage^2) x 100.

Constant-voltage LED strip voltage drop solved for the run length, by name.

Standard low-voltage LED-strip loading relation; the strip datasheet governs.

Estimate. AHJ and licensed professional govern.

Field names used by the API: power_per_ft_w, supply_voltage_v, resistance_per_ft, drop_tolerance_pct, max_run_ft