Waste Storage Facility Volume (NRCS 313)

Waste storage volume by NRCS 313: manure, wastewater, bedding, precipitation, and freeboard.

Run the calculator

Example

You enter

You get

Details, formula, and sources

NRCS 313 waste storage sizing: total = (daily manure + wastewater + bedding) x storage_days + area x (net precip + 25-yr storm)/12 + freeboard. An uncovered pit must bank the rain and the 25-year storm on its own surface, or it overtops in a wet spring; minimum storage 120 days. A planning aid, not the engineer of record.

manure_volume = (daily_manure + wastewater + bedding) x storage_days; precip_storm_volume = surface_area x (net_precip + storm) / 12; freeboard_volume = surface_area x freeboard_in / 12; total = the sum.

NRCS Conservation Practice Standard 313 / ASABE D384 manure production, by name.

NRCS 313 and ASABE D384 are public standards; the engineer/planner of record governs the actual design.

Estimate. AHJ and licensed professional govern.

Field names used by the API: daily_manure_ft3, bedding_ft3, storage_days, surface_area_ft2, net_precip_in, storm_in, freeboard_in, manure_volume_ft3, precip_storm_ft3, freeboard_ft3, total_ft3