OSHA 1910.95 Noise Dose and TWA

Multi-row workshift dose with the OSHA 5 dB exchange formula, 8-hr TWA, and pass / fail against the 85 dBA action level and 90 dBA PEL.

Run the calculator

Formula and source

T_hr = 8 / 2^((L - 90) / 5). D_pct = sum(C_i / T_i) * 100. TWA_dBA = 16.61 * log10(D / 100) + 90. Levels below 80 dBA contribute zero to the OSHA dose.

OSHA 29 CFR 1910.95(b) Appendix A and Table G-16a.

Audience

This tile is built for carpentry and the adjacent professions in the Cross-Trade Utilities group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.