Pipe Pressure Rating and Required Wall (ASME B31.1)

The ASME B31.1 internal-pressure relation both directions.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Maximum allowable pressure from a wall thickness, or the minimum wall a design pressure demands - tying OD, wall, allowable stress S, weld-joint factor E, and the y-coefficient together (4 in Sch 40 A106-B -> ~1,637 psi). The allowable stress, joint factor, and y-coefficient are read from the applicable code edition's tables; a design screen, not a stamped calculation. The engineer of record and the AHJ govern.

allowable: P = 2 S E (t_avail - A) / (D - 2 y (t_avail - A)), t_avail = wall x (1 - mill_tol). required wall: t = P D / (2 (S E + P y)) + A. ASME B31.1 internal-pressure design.

ASME B31.1 Power Piping pressure-design relation, by name (B31.3 Process Piping uses the same form with its own allowables). The allowable stress S, joint factor E, and y-coefficient are read from the code edition's tables.

The internal-pressure design equation (Barlow for the first cut, the B31.1 form for the real one) is public; the material allowable stress, joint factor, and y-coefficient are read from the applicable code tables.

Estimate. AHJ and licensed professional govern.

Field names used by the API: od_in, wall_in, allow_stress, joint_factor, y_coeff, mill_tol_frac, mode, p_allow