Population Equivalent (Organic Load)

The population equivalent of a discharge, figured three ways.

Run the calculator

Example

You enter

You get

Details, formula, and sources

From BOD (0.17 lb/capita/day), flow (100 gpd/capita), and suspended solids (0.20 lb/capita/day) -- with the GOVERNING value being the largest, not BOD alone. A 0.5 MGD cannery at 600 mg/L BOD is worth ~14,700 residents in oxygen demand though its gallons look like 5,000; billing on flow alone under-charges it.

bod_load = MGD x BOD x 8.34; PE_bod = bod_load / 0.17; PE_flow = gpd / 100; PE_ss = ss_load / 0.20; PE = max(PE_bod, PE_flow, PE_ss).

Population equivalent (organic load), standard sanitary engineering, by name.

The per-capita loading bases and the population-equivalent relation are public sanitary-engineering conventions; the pretreatment ordinance and the authority govern.

Estimate. AHJ and licensed professional govern.

Field names used by the API: flow_mgd, bod_mg_l, ss_mg_l, pe_bod, pe_flow, pe_governing