Pump Sizing
Required head and flow.
Formula and source
Total dynamic head TDH = static lift + friction loss + velocity head + pressure required at outlet. Brake HP = (GPM × TDH) / (3960 × pump_efficiency).
Hydraulic Institute by name; Hazen-Williams (AWWA M11 5th ed.) for friction term.
Audience
This tile is built for plumbers and the adjacent professions in the Plumbing and Gas group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.
Related tools
Posture
Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.