Roof Board Fastener and Plate Count by Zone

Fasteners and plates for mechanically-attached roof insulation, by wind-uplift zone.

Run the calculator

Example

You enter

You get

Details, formula, and sources

fasteners = field boards x field rate + perimeter boards x perimeter rate + corner boards x corner rate; plates = fasteners (one each). 100 field boards at 8, 20 perimeter at 12, and 5 corner at 16 is 1,120 fasteners and plates; a high-wind field pattern of 12 raises it to 1,520. The zone densities come from the manufacturer's FM or UL uplift design. Distinct from shingle and panel fasteners.

fasteners = field_boards x field_per_board + perimeter_boards x perimeter_per_board + corner_boards x corner_per_board; plates = fasteners.

Roof-board fastener identity by name (sum of zone boards x zone rate; one plate per fastener); first-principles count arithmetic.

The count arithmetic is public first-principles; the zone fastening densities come from the manufacturer's wind-uplift design (no copyrighted uplift table reproduced).

Estimate. AHJ and licensed professional govern.

Field names used by the API: field_boards, field_per_board, perimeter_boards, perimeter_per_board, corner_boards, corner_per_board, fasteners, plates