Septic Pump / Dose Tank Volume

Net dose per cycle, pumped volume per cycle and per day.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Net dose per cycle, pumped volume per cycle and per day, and the dose-to-void ratio for a timed-dose pressure-distribution field. Per the USEPA Onsite Wastewater Treatment Systems Manual; the dose count and float settings on the permit drawing govern.

Net dose = daily flow / doses per day; pumped per cycle = net dose + drainback; pumped per day = pumped per cycle x doses; dose-to-void ratio = net dose / drainback (target >= 5).

USEPA Onsite Wastewater Treatment Systems Manual (EPA/625/R-00/008); university onsite-wastewater extension low-pressure-pipe design guidance, by name.

Free at epa.gov/septic. Extension LPP design guidance free on land-grant university extension sites.

Estimate. AHJ and licensed plumber / gas fitter govern. Verify against the IPC / IFGC edition adopted in your jurisdiction.

Field names used by the API: daily_flow_gpd, doses_per_day, drainback_gal, net_dose_gal, pumped_per_dose, pumped_per_day, void_ratio