Cantilever Sheet Pile Wall Penetration Depth

Rankine coefficients, active force, and the embedment that balances moments about the toe.

Run the calculator

Example

You enter

You get

No published worked example is on file for this calculation. It is checked against a hand-worked derivation of its method and an independent reference test.

Details, formula, and sources

ScopeIncreased by the conventional 20 to 40% that USS calls the margin. The worked 12 ft wall needs a 25 ft pile, 52% of it below the excavation. Deflection often governs instead and this does not compute it.

Formula or tableKa = tan^2(45 - phi/2); Kp = tan^2(45 + phi/2); Pa = 0.5 Ka gamma H^2 at H/3; embedment from moments about the toe on the gross pressures, Kp D^3 = Ka (H + D)^3; max moment where shear is zero, z = H sqrt(Ka) / (sqrt(Kp) - sqrt(Ka)); S = M / allowable stress.

Source and editionRankine earth pressure with the simplified (Blum) cantilever moment balance, increased by the conventional 20 to 40% (USS Steel Sheet Piling Design Manual). The geotechnical report, the applicable building code, and the design engineer govern.

Free accessRankine's relations are public; the soil parameters come from the site's own investigation.

What governsEstimate. AHJ and licensed professional govern.

API field namesretained_height_ft, friction_angle_deg, unit_weight_pcf, increase_factor_pct, allowable_stress_psi, ka, kp, active_force_plf, theoretical_depth_ft, design_depth_ft, total_length_ft, embedment_share_pct, depth_to_max_moment_ft, max_moment_ftlb_per_ft, section_modulus_in3_per_ft

Related tools