Minimum Sound Shell for an Allowable Trunk Strength Loss

The minimum radial sound-wood shell thickness for a maximum acceptable strength loss.

Run the calculator

Example

You enter

You get

Details, formula, and sources

t = (D/2) x (1 - (loss/100)^(1/3)). A 24-in trunk held to a 29.6% loss needs a 4.0-in shell (t/R 0.33, just above the Mattheck 0.30 trigger). Because loss goes as the CUBE of the hollow ratio, the minimum shell is small - a thin shell still holds most of the strength. Flags a shell below the Mattheck t/R 0.30 concern. An open cavity is far weaker; a screen, not a load rating.

min_shell t = (D/2) x (1 - (loss/100)^(1/3)); the inverse of loss_pct = ((D - 2t)/D)^3 x 100; t_over_R = t / (D/2); concern when t/R < 0.30.

Hollow-trunk strength-loss screen (Wagener 1963; Smiley & Fraedrich 1992; Mattheck & Breloer t/R; ISA TRAQ), by name, solved for the shell thickness.

The Wagener cube-law loss and the Mattheck t/R rule are published arboricultural results; a qualified arborist and a TRAQ assessment govern.

Estimate. AHJ and licensed professional govern.

Field names used by the API: diameter_in, allow_loss_pct, min_shell_in, min_t_over_r