UV Dose and Target Check

Delivered UV dose, checked against a validated target.

Run the calculator

Example

You enter

You get

Details, formula, and sources

The delivered ultraviolet dose (intensity x exposure time, mW.s/cm^2 = mJ/cm^2) checked against a validated target (default 40 mJ/cm^2). A short dose points to an aged lamp, a fouled sleeve, or low UV transmittance. USEPA UV Disinfection Guidance; the validated reactor dose and the state primacy agency govern compliance.

dose_mj_cm2 = intensity_mw_cm2 x exposure_time_s (mW.s/cm^2 = mJ/cm^2); meets the target if dose >= target_dose (default 40 mJ/cm^2), else short.

USEPA UV Disinfection Guidance Manual (EPA 815-R-06-007) by name; dose = intensity x time, no edition cycle.

The dose relation is public; the validated reactor dose and the state primacy agency govern compliance.

Estimate. Operator of record and primacy agency govern.

Field names used by the API: intensity_mw_cm2, exposure_time_s, target_dose_mj_cm2, dose_mj_cm2, meets