Wire-Rope Breaking-Strength Estimate and WLL

Field estimate of wire-rope breaking strength and its working load limit.

Run the calculator

Example

You enter

You get

Details, formula, and sources

A field estimate of wire-rope minimum breaking strength (construction factor x diameter^2, default 46 tons/in^2 for IPS 6x19, editable) and the working load limit at a design factor (default 5:1). An ESTIMATE only - the manufacturer's certified breaking strength governs, and unmarked or uncertified rope must not be placed in service.

mbs_tons = construction_factor x diameter_in^2 (default 46 tons/in^2 for IPS 6x19); wll_tons = mbs_tons / design_factor (default 5).

Wire Rope Users Manual rule-of-thumb (by name); MBS = factor x d^2, no edition cycle.

An ESTIMATE only; the manufacturer's certified breaking strength governs. Do not place unmarked or uncertified rope in service.

Estimate. Head rigger and manufacturer working-load-limit charts govern. Inspect every piece of hardware before the show.

Field names used by the API: diameter_in, construction_factor, design_factor, mbs_tons, wll_tons

Related tools