Accessible Toilet Compartment Sizing (2010 ADA Standards 604.8)

Two compartments can be owed, and the second is triggered by an OR that gets read as an AND.

Run the calculator

Example

You enter

You get

Details, formula, and sources

an AMBULATORY compartment is required in addition to the wheelchair one where six or more compartments are provided OR where urinals and water closets total six or more fixtures. Four stalls and three urinals is seven fixtures and owes one, which is the case that gets missed because the stalls get counted and the urinals do not. The wheelchair compartment is 60 in wide and 56 in deep for a WALL HUNG water closet or 59 in for a FLOOR MOUNTED one, so a fixture substitution that moves no partition can fail the stall. And the ambulatory width is a WINDOW, 35 to 37 in: a 40 in stall is too WIDE to qualify, because the point is grab bars on both walls within reach.

wheelchair accessible compartment: width >= 60 in; depth >= 56 in for a wall hung water closet or >= 59 in for a floor mounted one. Ambulatory accessible compartment: depth >= 60 in and 35 in <= width <= 37 in. An ambulatory compartment is required in addition where compartments >= 6 OR (urinals + water closets) >= 6.

2010 ADA Standards for Accessible Design, 213.3.1, 604.8.1.1, and 604.8.2.1. A US federal standard in the public domain, quoted directly.

The 2010 ADA Standards are published in full at no cost at ada.gov and by the US Access Board.

Estimate. AHJ and licensed professional govern.

Field names used by the API: compartment_count, urinal_count, water_closet_count, wheelchair_width_in, wheelchair_depth_in, wc_mounting, ambulatory_provided, required_wheelchair_depth_in, wheelchair_depth_deficit_in, wheelchair_width_deficit_in, fixture_total, other_mounting_depth_in