Concrete Anchor Steel Strength (ACI 318-19 17.6.1 / 17.7.1)

The steel strength of an anchor bolt, the other half of every 'least of steel and concrete' anchor check.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Ase = (pi/4)(da - 0.9743/n)^2 from the thread callout, futa capped at min(1.9 fya, 125 ksi), Nsa = Ase futa (phi 0.75), Vsa = 0.6 Ase futa (phi 0.65, cast-in headed/hooked bolts). A 5/8-11 A307 checks 9.8 kip design tension and 5.1 kip design shear. ACI Chapter 17's own steel check - the AISC J3 bolt checks are the structural-connection path, with different numbers.

Ase = (pi/4)(da - 0.9743/n)^2; futa <= min(1.9 fya, 125,000 psi); Nsa = Ase futa, phiNsa = 0.75 Nsa (ductile, tension); Vsa = 0.6 Ase futa, phiVsa = 0.65 Vsa (ductile, shear, cast-in headed/hooked bolts).

The ACI 318-19 Sections 17.6.1 (steel strength in tension) and 17.7.1 (steel strength in shear, Eq. 17.7.1.2b) with Table 17.5.3 phi factors, by name; the Ase expression is the R17.6.1.2 commentary formula (also AISC Manual Table 7-18).

ACI 318 is readable free through the ACI online reading room at concrete.org; the Chapter 17 anchoring provisions are in the published code.

Estimate. AHJ and licensed professional govern.

Field names used by the API: anchor_dia_in, threads_per_in, fya_psi, futa_psi, ase_in2, futa_used_psi, nsa_lb, phi_nsa_lb, vsa_lb, phi_vsa_lb