Containment Air Balance
Required net negative CFM via Q = 2610 * A * sqrt(delta_P) and recommended NAM count.
Formula and source
Orifice flow Q = 2610 × A × sqrt(ΔP) (cfm; A in ft², ΔP in inches WC). Recommended NAM count = required_negative_flow / per-NAM rated CFM.
Classical orifice-flow theory; constant 2610 from ASHRAE Fundamentals derivation. IICRC S520-2024 §12 for containment guidance.
Audience
This tile is built for restoration and the adjacent professions in the Water Damage and Mold Restoration group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.
Related tools
Posture
Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.