Lavatory Height and Bathtub Clearance (2010 ADA Standards 606, 607)

Two rules short enough to skip and specific enough to fail a remodel that measured fine everywhere else.

Run the calculator

Example

You enter

You get

Details, formula, and sources

The lavatory limit of 34 in is to the front of the HIGHER of the rim or the COUNTER -- so a vessel sink or a thick stone top fails a fixture that was specified correctly, and the fixture was never the problem. Metering faucets must stay open 10 SECONDS, longer than most ship set. And the clearance in front of a tub runs the LENGTH of the tub at 30 in wide, extending 12 in PAST the head-end wall where there is a permanent seat -- so a 60 in tub needs 72 in of floor, which is the part that gets drawn short.

lavatory: the front of the higher of the rim or the counter surface is 34 in maximum above the finish floor; hand-operated metering faucets remain open 10 seconds minimum. Bathtub: clearance in front extends the length of the tub and is 30 in wide minimum, extending 12 in beyond the wall at the head end where a permanent seat is provided - so the required clearance length = tub length + 12 in with a seat, and the tub length without.

2010 ADA Standards for Accessible Design, 606.3, 606.4, 606.5, 607.2, and 607.3. A US federal standard in the public domain, quoted directly.

The 2010 ADA Standards are published in full at no cost at ada.gov and by the US Access Board.

Estimate. AHJ and licensed professional govern.

Field names used by the API: rim_height_in, counter_height_in, metering_seconds, tub_length_in, permanent_seat, clear_width_in, clear_length_in, governing_lav_height_in, lav_excess_in, metering_deficit_s, required_clear_length_in, clear_length_deficit_in, clear_area_sf