Water Closet Location and Seat Height (2010 ADA Standards 604)

The 18 in everyone remembers is a WINDOW of 16 to 18, and the plumbing code's 15 in minimum is not inside it.

Run the calculator

Example

You enter

You get

Details, formula, and sources

The 18 in everyone remembers is a WINDOW of 16 to 18, and the plumbing code's 15 in minimum is not inside it -- so a closet roughed at the IPC minimum is code-compliant and ADA-noncompliant by an inch, while one set at a generous-looking 20 in fails the other end. The seat is 17 to 19 in to the TOP OF THE SEAT, not the rim, so a thick seat moves a compliant bowl either way. And the 60 x 56 in clearance is CLEARANCE, not a compartment: it must be clear of everything, which is why a lavatory that fits the room can still fail by standing in it.

centerline 16 in minimum to 18 in maximum from the side wall or partition; seat height 17 in minimum to 19 in maximum measured to the top of the seat; clearance 60 in minimum from the side wall and 56 in minimum from the rear wall; flush controls on the open side except in an ambulatory accessible compartment.

2010 ADA Standards for Accessible Design, 604.2, 604.3.1, 604.4, and 604.6. A US federal standard in the public domain, quoted directly.

The 2010 ADA Standards are published in full at no cost at ada.gov and by the US Access Board.

Estimate. AHJ and licensed professional govern.

Field names used by the API: centerline_in, seat_height_in, clear_side_in, clear_rear_in, flush_side, ambulatory, centerline_deficit_in, seat_deficit_in, clear_area_sf, required_area_sf, side_deficit_in