Overflow Scupper Sizing (Weir Flow)

Secondary (overflow) scupper as a rectangular weir.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Q = 3.33 L H^1.5 (cfs, feet), contracted 3.33(L - 0.2H)H^1.5. A 6 in scupper at 3.5 in head passes 118 gpm (104 contracted); a wide 12 in / 2 in scupper passes 102 gpm. Head is at the blocked-primary condition (IPC 1108 / FM Global). The code and roof-loading check govern.

Q = 3.33 L H^1.5 (cfs, L and H in ft); contracted Q = 3.33 (L - 0.2 H) H^1.5; gpm = cfs x 448.8.

The rectangular (Francis) weir capacity of an overflow scupper, secondary roof drainage per IPC 1108 / FM Global, by name.

The Francis rectangular-weir formula is public; the secondary-drainage requirement is in the published IPC (Section 1108) and FM Global data sheets.

Estimate. AHJ and licensed professional govern.

Field names used by the API: length_in, head_in, q_gpm, q_gpm_contracted

Related tools