Scupper Width for a Required Overflow Flow

The scupper width for a required overflow flow at a design head.

Run the calculator

Example

You enter

You get

Details, formula, and sources

from the rectangular weir Q = 3.33 L H^1.5. L = Q / (3.33 H^1.5) suppressed, or + 0.2 H for a contracted (narrow) scupper. 118 gpm at a 3.5 in head needs a 6.0 in opening (6.7 in contracted). Round the width UP; head is at the blocked-primary condition (IPC 1108 / FM Global). The code and roof-loading check govern.

L = Q / (3.33 H^1.5) (suppressed); L = Q / (3.33 H^1.5) + 0.2 H (contracted); Q_cfs = required_gpm / 448.8; L and H in ft, width reported in inches.

The rectangular (Francis) weir capacity of an overflow scupper (secondary roof drainage per IPC 1108 / FM Global), by name, solved for the width.

The Francis rectangular-weir formula is public; the secondary-drainage requirement is in the published IPC (Section 1108) and FM Global data sheets.

Estimate. AHJ and licensed professional govern.

Field names used by the API: required_gpm, head_in, width_suppressed_in, width_contracted_in