Pump Wire-to-Water Efficiency
Water HP, brake HP estimate, and wire-to-water % with good/ok/degraded category.
Formula and source
Water HP WHP = (GPM × TDH) / 3960. Brake HP estimate BHP = motor_kW × 1.341 × motor_eff × drive_eff. Wire-to-water % = WHP / motor_HP × 100. Categories: ≥ 65% good, ≥ 50% ok, < 50% degraded.
Hydraulic Institute (HI) standards by name; ANSI/HI 14.6 (Rotodynamic Pumps for Hydraulic Performance Acceptance Tests) by name.
Audience
This tile is built for water operators and the adjacent professions in the Water and Wastewater Operations group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.
Related tools
Posture
Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.