Hot Water Recirc Loop Sizing (ASPE)

Per ASPE Data Book Vol. 4 Ch. 6: derives heat-loss rate, required GPM from set-point delta.

Run the calculator

Example

You enter

You get

Details, formula, and sources

Friction head via Hazen-Williams, and recommended pump size from loop length / pipe size / insulation / temperatures. ASHRAE 90.1-2022 §7.4.4 governs recirc control.

q_per_ft = U * (T_hot - T_ambient). Q_total = q_per_ft * L. GPM = Q_total / (500 * set-point-delta). Friction head via Hazen-Williams (C=140 for copper). Pump-size ladder: 1/40 / 1/25 / 1/20 / 1/12 / 1/6 / 1/4 HP, with 25% wet-rotor wire-to-water efficiency factor.

ASPE Data Book Vol. 4 (Plumbing Engineering Design Handbook) Chapter 6 simplified per-foot heat-loss method. ASHRAE 90.1-2022 §7.4.4 for recirculation control.

aspe.org for TOC.

Estimate. AHJ and licensed plumber / gas fitter govern. Verify against the IPC / IFGC edition adopted in your jurisdiction.

Field names used by the API: loop_length_ft, nominal_size_in, insulation_in, hot_supply_F, ambient_F, set_point_delta_F, q_per_ft_btu_hr, Q_total_btu_hr, gpm_required