Thermal Imager Delta-T Reference
Typical surface-temperature differentials for moisture, insulation, and electrical hotspots.
Formula and source
(reference page; no compute) Thermal-imager delta-T interpretation: compare inspected component temperature against an unloaded reference of the same construction; ≥ 1 °C above reference flags moisture migration, ≥ 5-10 °C flags an active issue per IR-imaging engineering practice.
ASTM C1153 (Standard Practice for Location of Wet Insulation in Roofing Systems) by name; FLIR / Fluke published thermography training materials.
Audience
This tile is built for restoration and the adjacent professions in the Water Damage and Mold Restoration group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.
Related tools
Posture
Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.