Weld Travel Speed for a Target Heat Input

Travel speed TS = (60 V I eta)/(1000 HI) to hold a target heat input; travel at or above it to stay at or under the limit. GMAW 24 V, 200 A, eta 0.8, 40 kJ/in -> 5.76 in/min; a 25 kJ/in ceiling forces 9.22 in/min. The qualified WPS governs.

Run the calculator

Formula and source

TS = (60 x V x I x eta) / (1000 x HI); check HI = (60 V I eta)/(1000 TS).

The AWS/ASME arc heat-input relation solved for travel speed, by name.

Audience

This tile is built for trades and the adjacent professions in the Carpentry and Construction group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.