Drying Log (IICRC S500 Boundary Test)

Multi-row drying log: ambient / chamber paired daily readings, per-day boundary-humidity pass (chamber GPP must trend below ambient GPP), chamber GPP trend slope (GPP/day), and dry-down completion estimate. Up to 14 readings. Per IICRC S500-2021.

Run the calculator

Formula and source

Per reading: GPP = humidity-ratio * 7000 from temperature_F / RH via the bundled psychrometric helper. Boundary-pass: chamber_GPP < ambient_GPP. Trend: linear regression of chamber_GPP vs day_index (least-squares). Estimated days-to-target = (target - intercept) / slope - last_day, when slope is negative.

IICRC S500-2021 (Standard for Professional Water Damage Restoration). Public-domain boundary-humidity test method; IICRC governs acceptance.

Audience

This tile is built for restoration and the adjacent professions in the Water Damage and Mold Restoration group. The interactive calculator runs entirely in your browser. No account, no fee, no advertising, no tracking.

Related tools

Posture

Rough Logic answers the math question the working professional asks on the job. The site is a calm, fast, ad-free, account-free, ever-free reference. It does not interpret code. It does not replace the licensed professional. It does not store your inputs. The Authority Having Jurisdiction governs all installations and inspections.