Ligation Insert:Vector Molar Ratio

Insert mass to add for a target insert:vector molar ratio (insert ng = ratio x insert bp/vector bp x vector ng).

Run the calculator

Example

You enter

You get

Details, formula, and sources

Insert mass to add for a target insert:vector molar ratio (insert ng = ratio x insert bp/vector bp x vector ng), plus each in picomoles at 650 g/mol per bp. A short insert needs less mass, not equal mass; equal masses over-represent small fragments.

insert_ng = ratio x (insert_length / vector_length) x vector_ng; vector_pmol = vector_ng / (vector_length x 650) x 1e3; insert_pmol = ratio x vector_pmol.

Ligation insert:vector molar-ratio setup (standard molecular cloning), by name.

Standard molecular-cloning bench relation; the enzyme protocol and fragment ends govern.

Estimate. AHJ and licensed professional govern.

Field names used by the API: vector_ng, vector_length_bp, insert_length_bp, molar_ratio, insert_ng, vector_pmol, insert_pmol