Drying-Chamber Fresh-Air / CO2 Buildup

Required fresh-air exchange (cfm) and air changes per hour to hold a target CO2.

Run the calculator

Example

You enter

You get

Details, formula, and sources

From a mass balance against the outdoor concentration. Per ASHRAE 62.1; complements chamber-turnover. IICRC S500 governs the drying plan.

Q_fresh (cfm) = CO2 generation (cfm) x 1e6 / (C_indoor_ppm - C_outdoor_ppm); ACH = Q_fresh x 60 / containment_volume_ft3.

ASHRAE 62.1 ventilation-rate mass-balance basis, by name.

ASHRAE-published; the steady-state mass balance is public. IICRC S500 governs the drying plan.

Estimate. AHJ and licensed professional govern.

Field names used by the API: containment_volume_ft3, co2_generation_cfm, target_indoor_ppm, outdoor_ppm, fresh_air_cfm, ach