Required Fall-Arrest Clearance (ANSI Z359)

The clearance a personal fall-arrest system needs below the anchor so the worker does not strike the level.

Run the calculator

Example

You enter

You get

Details, formula, and sources

RFC = free-fall distance + deceleration distance + worker height (D-ring to feet) + safety margin. A 6 ft free fall, 3.5 ft deceleration (the Z359 lanyard cap), 5 ft worker, and 3 ft margin needs 17.5 ft. Enter each explicitly - free-fall depends on the anchor position; an SRL cuts both the free-fall and deceleration. Per ANSI Z359.1 / OSHA 1926 Subpart M; the equipment instructions and a competent person govern.

required_clearance = free_fall_distance + deceleration_distance + worker_height (D-ring to feet) + safety_margin; margin = available_clearance - required_clearance; adequate when margin >= 0.

ANSI Z359.1 (Fall Protection Code) and OSHA 1926 Subpart M fall-clearance calculation, by name.

The additive fall-clearance model is public (ANSI Z359 / OSHA 1926 Subpart M); OSHA standards are free at osha.gov, the Z359 standards are licensed.

Estimate. AHJ and licensed fire protection engineer govern.

Field names used by the API: free_fall_distance_ft, deceleration_distance_ft, worker_height_ft, safety_margin_ft, available_clearance_ft, required_clearance_ft, margin_ft